Pelletofen soleo.nrg V12
Pellet panorama with fantastic flame pattern and vertical smoke pipe connection
The combustion chamber of a room-sealed pellet stove is completely airtight. In addition, room-sealed wodtke pellet stoves have a tightly closing (TYPE CC) firebox door. In a pellet stove that operates independently of the ambient air, the oxygen required is not supplied from the room in which it is installed, but via a combustion air supply connected to the outside or via an exhaust air chimney. A pellet stove tested for room-sealed operation in accordance with EN 16510 is therefore ideal for installation in very airtight buildings, such as low-energy or passive houses, in combination with a controlled residential ventilation/ventilation system.
Of course, all room-sealed pellet stoves and wood-burning stoves from wodtke can also be operated in a room-sealed manner, i.e., without an external air supply.
In any case, you should involve your local district chimney sweep (building inspector for combustion appliances) at an early stage of your planning. Information on whether your desired stove has been tested and approved for room-sealed operation according to EN 16510 can be found in the operating manual of the respective model.
- Integrated vertical flue gas system/Vertical flue pipe connection
- Automatic cleaning program during operation
- Possibility of infinitely variable room temperature control
- Possibility of room air-independent connection - enables simultaneous operation with controlled ventilation of the living space
- Patented, especially safe combustion air technology with multiple electronic monitoring
- Microprocessor controlled: For an effective combustion with high efficiency, fuel and combustion air quantity are precisely matched to each other.
- up to 36 h running time with only one filling
- Comfortable operation at the furnace or via external thermostat
- very quiet operation, as no additional convection air blower is required
- easy cleaning due to cast iron sliding grate
- large ash pan
- childproof door lock
- height-adjustable feet
Adjustment range 2 - 6 or 2 - 8 kW
Spatial heating capacity: min. 40 m² / max. 160 m²
optimized for the combustion of wood pellets
Smoke pipe connection vertical ∅ 80 mm - expandable to ∅ 100 mm
Width 54 cm, depth 63 cm, height 120 cm
- 2nd stage of the 1st BImSchV fulfilled
- Nominal heat output 6 or 8 kW
- Spatial heating capacity 40 m² to 160 m² (min./max. output) at 50 Watt/m² demand
- Fuel Wood pellets with ash content < 0.7%
- CO content in exhaust gas < 0.02 % vol.
- 6kW
Flue gas temperature 104°C - 189°C
Exhaust gas mass flow 3.0 - 4.7 g/s
Energy efficiency class*: A++** / A+
- 8kW
Flue gas temperature 104°C - 200°C
Exhaust gas mass flow 3.0 - 5.4 g/s
Energy efficiency class*: A+
* Energy efficiency classes in the range from A++ to G
** For commissioning with control technology FT1/UT1/UT2/TC1 - Required delivery pressure (chimney draught) 12 PA
- Multiple occupancy with safety device possible
- Tested in accordance with EN 16510-2-6
- Room air-independent operation possible (Type CC, tested and approved according to EN 16510)
- Storage container for approx. 18 kg pellets
- E-power consumption < 50 W
- E-ignition short term 250 W
- Weight 150 - 155 kg